Roofs

The roof keeps weather out of the whole home, so small mistakes — missing bracing, poor ventilation or loose tiles — can have large consequences.

Independent revision notes, not a design specification. The public references below are for England; requirements differ across the UK. Use current local regulations, the approved project design and manufacturer instructions for decisions on site.

Trussed rafters and bracing

Trussed rafters are engineered components and must not be cut or altered on site. They should be set at the designed spacing, held plumb and braced with diagonal, longitudinal and chevron bracing as shown on the bracing drawing. Restraint straps tie the roof to the walls and gable ends.

Ventilation and condensation

Cold roofs need ventilation at the eaves, and often the ridge, to remove moist air that would condense on cold timbers. Insulation must not block the eaves airflow; trays or spacers keep the path open. Vapour-permeable underlays can reduce the ventilation needed when used as their certification allows.

Tiles and slates

Battens must be the correct grade and size, and tiles and slates fixed according to the manufacturer's wind uplift calculation. Edges, ridges and hips are now usually mechanically fixed rather than relying on mortar alone.

  • Underlay lapped correctly with a drape between rafters.
  • Minimum pitch for the chosen tile respected.
  • Lead flashings and soakers at abutments.

Flat roofs

Flat roofs need a designed fall to outlets so water does not pond, and coverings laid by trained installers. Upstands at walls and rooflights should be high enough to stop water getting behind the waterproofing.

Start with the roof design, not the tile

Roof performance depends on the structure, covering, insulation, ventilation and junctions working together. Check the roof pitch and exposure against the selected covering, and use the specified fixing schedule. A tile that suits one sheltered roof may need a different fixing arrangement elsewhere. Battens, underlay and accessories must also be appropriate for the chosen system rather than selected only by appearance.

Truss drawings identify bearings, bracing and restraint. Coordinate tanks, plant, rooflights and other loads before erection so that the structure accounts for them. Do not remove webs to create storage or route services without the designer's approval. During construction, roof access and handling need a safe method: neither rooflights nor an apparently intact sheet should be assumed capable of supporting a person.

Inspect the airflow and water routes

For a ventilated roof, trace a clear air path through the intended openings. Insulation pushed tightly into the eaves can obstruct it even where a vent grille is present. The correct arrangement depends on the roof build-up and underlay certification. Ventilation should not be improvised as a repair without first assessing the cause of condensation, moisture sources and the air and vapour control layers.

At valleys, abutments and rooflights, check that water is directed onto the covering or into a suitable outlet, not behind the waterproof layer. Junctions are more vulnerable than broad uninterrupted slopes. Inspect laps, support and termination details before adjacent materials conceal them. A sealant bead on the outside is not a substitute for the designed flashing or waterproofing junction.

Flat-roof drainage and handover

Check falls and outlets against the approved design, taking account of the completed insulation and waterproofing arrangement. Standing water may reveal a low point or blocked outlet, but the appropriate response depends on the roof system. Keep debris out of drainage paths during construction and provide safe maintenance arrangements. Upstands and penetrations must be inspected as part of the waterproofing system, not treated as finishing extras.

  • Use the site-specific covering and fixing requirements.
  • Inspect bracing, restraint and roof junctions before concealment.
  • Keep specified airflow and drainage routes clear, and plan safe roof access.

Quick site checklist

  • Trusses unaltered and fully braced
  • Restraint straps fitted
  • Eaves ventilation kept clear
  • Tiles fixed to wind uplift requirements
  • Flat roofs falling to outlets

Worked revision questions

  1. 1. Can a truss web be removed to make space for a storage platform?

    Answer: No — obtain a structural design decision before any alteration.

    Trusses are engineered for stated loads and support conditions. Removing a member or adding storage loads can change the whole load path, not just the local detail.

  2. 2. Eaves vents are installed, but insulation blocks the space behind them. Is ventilation complete?

    Answer: No — the intended airflow route is obstructed.

    Openings only work when they connect to the roof void as designed. Reinstate the specified clear path without compromising the insulation and air-control details.

  3. 3. Why inspect a rooflight upstand before the surrounding finish is fitted?

    Answer: Its concealed waterproofing junction must be continuous and correctly terminated.

    An attractive external trim can hide an incomplete water barrier. Early inspection makes the critical lap and termination visible and allows defects to be corrected before covering.